Fully 60 Hz AC tested and guaranteed vintage tube preamp transformer. AC testing using an oscilloscope allows us to find and reject transformers with noisy outputs, which a simple resistance or continuity test will not reveal. Made in USA in amp1950s. No IEA date code found. Weighs 4 lbs 12 oz. Bolt spacings 63mm by 60mm. Quantity sometimes available - please enquire.
Here are the verified connections for this transformer:
Input: 117V
Outputs:
850 VAC center tapped
6.3 VAC center tapped
Two total 6.3 VAC outputs!
1300 VAC available on multitap secondary. grey pair is 1 V apart, 1300 VAC above one of the red pair
We use a standardized wire identification scheme featuring bright cable ties. In case of any ambiguity, 117V input will be wrapped with a black cable tie, red is high-voltage, yellow is 5V for rectifier, green is 6.3V, blue is 12.6V, white is 117V out for use as an isolation transformer or tubes with series heaters, purple is a second (or third!) 6.3V output. The voltages run a bit higher when run at modern AC levels instead of the 117 VAC that was specified in the 1950s and 1960s. Serial number T-022.