Sennheiser ADN CU1-UKAudio Distribution Network Central Control Unit~ with Manual & Disc (still sealed, unopened)
~ and Brand New UK 5A Power Lead

Condition Note: In good condition, and in full working order, with minor external wear. There are no rubber feet and there is a small dent in the facade, near the "go back" arrow button - see advert images, above.

CONTENTS:

This is the complete kit. It comprises:
- ADN CU1-UK central unit (Product Code: 502757) [ Serial Number: 1520204182 ]
- [STILL SEALED] Paper Manual plus DVD-ROM (including, among other things, the "Conference Manager" software, the "ADN Cable Calculator" software and the instruction manual for the overall conference system as PDF)
- UK 3-pin Mains Cable [brand-new, 5A fuse]



OVERVIEW:


FEATURES:
- Supplies and controls up to 40 discussion units
- Integrated PC with pre-installed control software
- Graphical user menu in multiple languages
- Transformer balanaced XLR In- and Ouput
- Media control protocol over Ethernet
- Ethernet, USB, and VGA interfaces
- Permanent malfunction monitoring and error diagnostics
- Low-noise fan for in-room use
- Premium quality made in Germany

The Audio Distribution Network CU1, a digital discussion central unit, powers and controls up to 40 (depending on cable length) connected delegate and chairperson units. It offers full configuration in a quick and easy way over the menu display in several languages. Alternatively the integrated software package‚ Conference Manager‘ can be used directly on the CU1 by connecting a Screen, Mouse and Keyboard. The intuitive workflow of the conference manager allows a fluent monitoring and control of the conference.
Any kind of media control system can be connected over Ethernet to allow easy control of the ADN system. With its low-noise fan the central unit can be used directly in the meeting without disturbing it.

The ADN CU1 central unit is part of the Sennheiser ADN conference system. The central unit controls the operation of the entire conference system. For wired operation, up to max. 40 ADN D1 delegate units and ADN C1 chairperson units can be directly connected to the central unit. For larger wired conference systems with up to max. 400 conference units, the central unit can also manage up to 15 ADN PS power supplies which in turn supply power the wired conference units.

For wireless conferencing, you can operate up to 150 ADN-W C1 and ADN-W D1 wireless conference units. For this, you require at least one ADN-W AM antenna module per central unit. With one antenna module, you can operate a maximum of 75 wireless conference units. Depending on room conditions, you may require several antenna modules. Please note that you can connect a maximum of four antenna modules to one central unit.

For configuring the conference system, you can either use the central unit's operating menu or the "Conference Manager" software. However, the full functionality of a wireless conference system can only be configured using the "Conference Manager" software. The software also allows you to control and monitor conferences via a graphical interface.

ADN C1 and ADN D1 wired conference units and ADN-W C1 and ADN-W D1 wireless conference units can be combined arbitrarily as long as you ensure correct set-up and cabling and comply with the specifications (a conference system can comprise a total of 400 conference units of which up to 150 can be wireless).

DIRECTIONS FOR RUNNING SOFTWARE:
Preparing to use the "Conference Manager" software:



Running the software installed on the central unit:

To use the "Conference Manager" software installed on the central unit, you require the following devices:

Screen:
Connection: 15-pin Sub-D VGA
Resolution: 800 x 600 pixels or higher
1024 x 768 or 1280 x 1024 pixels recommended

Mouse: Standard USB for Windows PCs

Keyboard:
Standard USB for Windows PCsSupported language layouts: e.g. English, German, French, Spanish, Italian, Dutch, Russian, Chinese, Japanese (for the complete list, refer to the ADN system manual)

- Use a Sub-D VGA cable to connect a screen to the VGA monitor output
- Connect the keyboard and the mouse to the two USB sockets
- Configure the screen, the keyboard and the mouse using the "Conference Manager" software (for detailed information, refer to the ADN system manual)
- Use a USB hub if the number of USB sockets on the central unit is not sufficient.

Running the software on a separate Windows PC:

To run the "Conference Manager" software on a separate Windows PC, the PC must meet the following system requirements:

Processor: Intel Pentium 4 or AMD Athlon XP, 2 GHz or more
RAM: Min. 1 GB, depending on your operating system
Hard disk: Min. 500 MB free hard disk memory
Drives: DVD-ROM
Interfaces/network: Ethernet 100 MBit/s
TCP/IP internet protocol: Internet Protocol version 4 (IPv4)
Screen Minimum resolution: 800 x 600 pixels
Recommended: 1024 x 768 pixels

Operating system:
Microsoft Windows XP Professional with SP3
Microsoft Windows Vista with SP2
Microsoft Windows 7
Microsoft Windows 8

- Use a network cable (Cat5) to connect the Ethernet socket of the central unit to the network interface of your PC.
You can also connect the PC and the central unit using a switch or similar.

- Install the "Conference Manager" software supplied on the DVD-ROM on your connected PC and configure the network (for detailed information, refer to the ADN system manual).

SPECIFICATIONS:

Nominal input voltage: 100 to 240 V~Mains frequency: 50 to 60 Hz
Power consumption: 245 W
Output voltage at RJ45 EtherCAT: 52.8 V
Nominal output current: max. 1.75
Temperature range:
operation: +5°C to +50°C
storage: −25°C to +70°C

Relative humidity:
operation: 10 to 80%
storage: 10 to 90%

Dimensions (W x H x D): approx. 417 x 100 x 345 mm
Weight: approx. 6.5 kg

XLR IN:
Input resistance: R IN > 10 kΩ

Input level:
max. +18 dBu
min. –18 dBu

Nominal level: +7.5 dBu

XLR OUT:
Output resistance: R OUT < 100 Ω
Frequency response: 20 Hz to 14.5 kHz; −3 dB
Output level: max. +11 dBu
Nominal level: +6 dBu
THD (at 1 kHz): < 0.02 % A-weighted at +7.5 dBu
Signal-to-noise ratio: > 80 dB A-weighted at +11 dBu


ARCHITECT'S SPECIFICATION:

A central control unit with integrated PC, control software package and digital processor is the hub of a digital discussion system. The central control unit shall supply 52.8 vDC power and control data through a proprietary network bus for controlling up to 40 discussion units.

The integrated control software can be controlled using the intuitive front panel display using multifunction control keys. Alternatively, the software can be accessed by connecting a standard VGA monitor, keyboard and mouse. The integrated software provides support in multiple languages. Full control over media control systems can be accomplished through an industry standard Ethernet network connection.

Fault monitoring and error diagnostics are provided; a full system diagnostics check is executed upon application of power to the unit. The conference manager software shall allow full control over all delegate stations and the audio and conference parameters, e.g. equalizing, conference modes and microphone limit.

The delegate discussion units shall be hot-swappable during the conference. Addressing shall be done automatically by order of cabling; alternatively the addresses shall be assignable manually in the conference manager software. Audio input and output ports are provided as transformer balanced XLR connections.

Audio frequency response shall be 100Hz to 14kHz. Input voltage range shall be -18dBu to +18dBu (XLR In). Maximum output level shall be +10dBV with a signal-to-noise ratio of greater than 80dB A-weighted at +18dBV. Total harmonic distortion shall be less than 0.01% A-weighted at +6dBV In and Out. Power consumption shall be 245W; operating temperature shall be +5°C to +50°C. The central control unit shall be housed in a stand-alone desktop housing; rack mounting shall be accomplished using optional rack mounting brackets.

Promoted similar listings













Listeda month ago
ConditionGood (Used)
Good condition items function properly but may exhibit some wear and tear.Learn more
Brand
Model
  • ADN CU1-UK
Categories
Year
  • 2010s
Made In
  • Germany

Product safety information may be available here.

Posh Shop

Redditch, United Kingdom
Joined Reverb:2024

Reverb Protection

Simple Returns, Secure Transactions, Human Support

Learn more

Secure Checkout

Reverb Gives

Your purchases help youth music programs get the gear they need to make music.

Oops, looks like you forgot something. Please check the fields highlighted in red.