Similar Listings

Burbank, CA, United States
$155
Phoenix, AZ, United States
$140
Burbank, CA, United States
$180
Pomona, CA, United States
$175
Pomona, CA, United States
$79
Morongo Valley, CA, United States
$75
Urbana, IL, United States
$82
Burbank, CA, United States
Originally $99.99, now $89 (11% price drop)
Burbank, CA, United States
Originally $180, now $148 ($32 price drop)
Minneapolis, MN, United States
$74

Module A-150-8 contains eight manually/voltage controlled switches. Each of the eight switches has a manual control button (Man.), a control voltage input (CV), a common Out / Input (O/I), and two In / Outputs (I/O1, I/O2). The switches are bi-directional, i.e. they can work in both directions, so can connect one input to either of two outputs, or either of two inputs to one output. Two LEDs show which in / output is active (i.e. which is connected to the common out / input). In addition the LEDs are used for the programming of the module:

For each unit the operating mode can be selected: Toggle or Level controlled. In Toggle mode the rising edge of the CV input or operating the manual control button changes the state of the switch. In Level mode the switch state is defined by the voltage applied to the CV input (low voltage = I/O1, high voltage = I/O2) or by the state of the manual control button (not pressed = I/O1, pressed = I/O2). The modes are programmed very easily: Operating the Toggle/Level button of the program section displays the current state of each switch with the LEDs: left LED on = Toggle mode, right LED on = Level mode. Operating the manual control button of the switch in question changes the toggle/level mode while the Toggle/Level button of the program section is operated. During the programming possibly patched CV signals have to be removed as the CV signals would interfere with the manual operating buttons during the programming process.

In addition it's possible to define master/slave groups. In such a group the upper unit (= master) controls also the state of the following switches provided that they are defined as slaves. Master/slave programming is also very simple: Operating the Master/Slave button of the program section displays the current state of each switch with the LEDs: left LED on = Master, right LED on = Slave. Operating the manual control button of the switch in question changes the master/slave mode while the Master/Slave button of the program section is operated. During the programming possibly patched CV signals have to be removed as the CV signals would interfere with the manual operating buttons during the programming process. When all 8 units are defined as master all switches are independent from each other. If for example the sequence is MSSSMSMS the control unit of the first switch also controls the switches 2, 3 and 4. The control unit of switch 5 also controls the switch 6, and the control unit of switch 7 also controls the switch 8. The current states of the slave switches are overwritten by the state of the master switch.
Technical Specs.:

  • Width: 12HP

  • Depth: 60mm

  • Current Draw: +12V : 40mA / -12V : 5mA

ConditionBrand New (New)
Brand New items are sold by an authorized dealer or original builder and include all original packaging.Learn more
Brand
Model
  • A-150-8
Categories
Made In
  • France

Modularsquare

Paris, France
Sales:3,165
Joined Reverb:2018

Reverb Gives

Your purchases help youth music programs get the gear they need to make music.

Carbon-Offset Shipping

Your purchases also help protect forests, including trees traditionally used to make instruments.

Oops, looks like you forgot something. Please check the fields highlighted in red.